This circuit gives an early
warning of the discharge of batteries. Zener diode D1 is chosen for the voltage below
which an indication is required (9V). Should the supply drop to below 7V, D1 will cease
conducting causing Q1 to shut off. Its collector voltage will now increase causing Q2 to
start conducting via LED and its limiting resistor R4. |